Open source · GPL-3.0-only
A free toxicology LIS
on a computer
your lab owns.
A free laboratory information system (LIS/LIMS) for small US clinical toxicology labs. It covers the work from the first order to the final report and runs on one computer in the lab.
- Works without internet
- No server to run
- Backup and export included
In development. Not clinically validated or ready for patient reporting.
Meet OpenBGA Toxicology LIMS.
A two-minute walkthrough of the application, from order to report, delivery and audit.
From order
to audit trail.
Each stage hands its work to the next, with identity, quality control and authorization checks along the way.
-
Order & accession
Orders, as the clinic sent them
Tests, diagnoses and supporting evidence are recorded exactly as the clinic supplied them; the application never fills any of them in. Receiving a specimen creates the accession and prints its barcode label.
-
Bench
Runs with their calibrators and controls
Worklists gather waiting specimens for each method. Results arrive from ASTM and Olympus AU400/AU640 analyzers and from LC-MS/MS result files, and quality control is recorded with the run.
-
Review
Every result technically reviewed
Results appear with their method, classification and provenance. A failed QC or an identity question holds the result, and each approval records who reviewed it and when.
-
Release
Released reports are versioned
Every hold is checked again at the moment an authorized person releases the PDF report. A correction creates a new revision and keeps the earlier one.
-
Deliver & bill
Handoffs with their evidence
Each fax, email, mail, courier or pickup is logged with whatever evidence is available, and an unknown or failed outcome is shown as unknown or failed. Billable services derive from the work performed, whether or not a result is positive.
-
Audit
A tamper-evident audit trail
Every change and every view of sensitive data is recorded and attributed to a personal account. The trail can verify its own chain.
Screens from the presentation recording, with demo data and a mocked engine. Select a screen to open it at full size.
The lab keeps
its own data.
Core laboratory work stays on the laboratory’s own computer. The application runs offline, and the lab can export all of its data.
- Local by design
- A standalone desktop application with no server to run. Analyzers can send results while the app is open, including while users are signed out.
- Backup and exit included
- Encrypted backups to the lab’s own disk, NAS or USB drive, restore tests, and a complete export. None of it needs a hosted service.
- Every action is attributed
- Personal accounts with two-factor sign-in or a security key, roles, and configurable separation of duties, including a one-person mode.
- Hosted services are optional
- A clinic portal, off-site backup, secure delivery, and EHR interfaces are separate future proposals. They would only relay copies; the LIS remains the system of record.
Questions about a free toxicology LIS.
What the software costs, who it is for, and how to try it.
Is OpenBGA Toxicology LIMS really free?
Yes. The application has no license fee, subscription or per-test charge. It is free software under GPL-3.0-only: a lab may use, study, change and share it. Backup, restore and complete data export are included.
Is it an LIS or a LIMS?
Laboratories that report patient results usually call their system a laboratory information system (LIS). Laboratory information management system (LIMS) is the broader term, and the two are often used interchangeably. OpenBGA Toxicology LIMS is built for patient testing: orders, specimens, results, review and reports.
Which laboratories is it for?
Small US clinical toxicology labs, such as physician-office labs and small independent labs, whose work fits on one computer. A standard catalog for urine and oral fluid drug testing loads as drafts for the lab to review and approve. Workplace, forensic and postmortem testing are not in scope.
How can I try it?
Download a development build for Windows, macOS or Linux, or build it from source. On first start, choose the demo laboratory: a separate workspace with a fictitious laboratory, clinics and patients, so no real patient information is needed.
Download or build from source.
Unsigned development installers for Windows, macOS and Linux are on the latest release page. Developers can also build the application from source.
You will need
- Rust through rustup; the repository pins its toolchain
- Node.js 24 and npm
- The Tauri 2 prerequisites for Windows, macOS or Linux
git clone https://github.com/openbga/toxicology-lims.git
cd toxicology-lims
npm ci
npm run tauri dev
Project status.
The requirements, architecture decisions and review standards are public. The quality guidance separates required checks from completed evidence and lists the remaining gaps.
| Available in development | Still ahead |
|---|---|
| Order-to-report workflow | Validation with a partner laboratory |
| Local backup, restore, and export tools | Signed installers and production verification |
| A development build running on macOS; Windows and Linux are targets | Decisions on additional workstations and optional hosted services |
| GPL-3.0-only source and project documentation | Trademark and remaining project governance decisions |
OpenBGA Toxicology LIMS is built with substantial AI assistance. People set the scope, research the requirements, challenge proposed designs, review the code, design the tests, test the application by hand and decide what needs more work.
License
Licensed under GNU GPL version 3 only (GPL-3.0-only). Commercial use and redistribution are permitted. Distributors must preserve the required notices, license covered works under GPLv3, and provide corresponding source as the license requires. Third-party material retains its own terms.
Development disclaimer
The application is built and tested on synthetic data. It is not clinically validated or ready for patient reporting. Neither AI-assisted development nor human review and testing guarantees correctness, security, regulatory compliance or fitness for clinical use.
Provided as is, with GPLv3’s warranty exclusions and liability limitations, subject to applicable law and written agreements. This notice does not change the license. Read the full disclaimer.
The source, requirements and decision records are on GitHub.