From raw materials to CoA.

OpenBGA QM LIMS (QM for quality management) is an open-source laboratory information management system for manufacturing quality-control laboratories. It records the sampling, testing, independent review and QC disposition of each material lot, and issues the signed certificate of analysis (CoA).

The code is licensed under the GNU Affero General Public License v3.0, and the source and documentation are public on GitHub.

You need an assigned account to sign in to the demo. Use synthetic data only.

Are you looking for support? Contact bgasoft.com.

Workflow

Analysts, reviewers and quality staff all work on the same lot record.

  1. Receive and sample

    Receive the lot into quarantine with its supplier, lot numbers, delivery document, quantity and containers, and what the examination on receipt found. Assign its approved specifications and sampling plan, for the general scope and for each market or customer the lot is for. Where two specifications state a test differently, quality decides with a signature which requirement applies. Record what the supplier's certificate states beside the specification, apart from the laboratory's own tests. Where your rule set allows it and the supplier is qualified for the material, a stated result can be accepted in place of a test, with an independent signature. Record which containers were sampled, where, when and by whom.

  2. Test and investigate

    Record numeric, count and qualitative observations, replicates and batch QC, or calculate a result from raw measurements with an approved formula. Each entry names the instruments and reagent lots used. A test performed by an approved contract laboratory is recorded from its report. The original result stays on record through any correction or out-of-specification investigation. When a specification or method is revised while a lot is being tested, quality can replace the lot's requirements with a signature; tests whose requirement changed are kept as superseded and repeated.

  3. Review and decide

    A reviewer who did not record the results signs the review. Quality then checks completeness, failures and open holds before signing the QC disposition.

  4. Issue and preserve

    Issue a versioned certificate of analysis. An amendment states its reason and links to the original certificate, which stays as issued.

Scope and current status

One system serves QC laboratories in pharma and biotech, supplements, food, chemicals and medical devices.

Approved configuration sets the requirements for each segment. Beyond sampling and testing, the system keeps equipment and reagent records, analyst qualifications and stability records.

OpenBGA QM LIMS is in development and uses synthetic data. Whoever deploys it remains responsible for intended-use validation and operational acceptance. A QC disposition recorded here is separate from the manufacturer's batch release.